  ip66 110 selv specification model cen-100-20 CEN-100-24 cen-100-30 cen-100-36 cen-100-54 cen-100-48 cen-100-42 dc voltage current range rated power output line regulation load regulation setup time voltage range note.4 frequency range power factor (typ.) efficiency (typ.) ac current (typ.) input inrush current (typ.) leakage current working temp. working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing over current short circuit over voltage over temperature 20v 24v 30v 36v 54v 48v 42v 0 ~ 4.8a 0 ~ 4a 0 ~ 3.2a 0 ~ 2.65a 0 ~ 1.77a 0 ~ 2a 0 ~ 2.28a 96w 96w 96w 95.4w 95.58w 96w 95.76w 2.0vp-p 2.7vp-p 3vp-p 3.6vp-p 5vp-p 4.6vp-p 4vp-p 10% 3.0% 5.0% 3000ms / 230vac 5000ms / 115vac at full load 90 ~ 295vac 127 ~ 417vdc 47 ~ 63hz pf>0.97/115vac, pf>0.95/230vac, pf>0.92/277vac at full load (pl ease refer to "power factor characteristic" curve) 88% 89% 90% 90% 91% 91% 90% 22.8 ~ 26v 28 ~ 32v 34 ~ 38v 41 ~ 46v 59 ~ 65v 54 ~ 60v 47 ~ 52v 1.4a/115vac 0.7a/230vac 60a/230vac <0.75ma / 240vac 95 ~ 110% protection type : constant current limiting, recovers automatically after fault con dition is removed hiccup mode, recovers automatically after fault condition is remove d -30 ~ +70 (refer to "derating curve") 20 ~ 95% rh non-condensing -40 ~ +80 , 10 ~ 95% rh 0.03%/ (0 ~ 50 ) 10 ~ 500hz, 5g 12min./1cycle, period for 72min. each along x, y, z axes 519.5khrs min. mil-hdbk-217f (25 ) 193*62.5*40.5mm (l*w*h) 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. derating may be needed under low input voltage. please check the static ch aracteristics for more details. 5. constant current operation region is within 65% ~100% rated output vol tage. this is the suitable operation region for led related application s, but please reconfirm special electrical requirements for some specific syste m design. 6. the power supply is considered as a component that will be operated in comb ination with final equipment. since emc performance will be affected by t he complete installation, the final equipment manufacturers must re- qualify emc directive on the complete installation again. 7. direct connecting to leds is suggested, but is not suitable for using add itional drivers. 0.6kg; 24pcs/15.4kg/1.11cuft protection type : shut down o/p voltage, re-power on to recover ripple & noise (max.) note.2 voltage tolerance note.3 environment safety & emc protection 100 10 (rth1) protection type : shut down o/p voltage, re-power on to recover withstand voltage isolation resistance i/p-o/p:3.75kvac i/p-fg:1.88kvac o/p-fg:0.5kvac ul8750, tuv en61347-1, en61347-2-13, j61347-1, j61347-2-13, ip 66 approved i/p-o/p, i/p-fg, o/p-fg: >100m ohms / 500vdc / 25 / 70% rh safety standards compliance to en55015, en61000-3-2 class c ( 65% load) ; en61000-3-3 compliance to en61000-4-2,3,4,5,6,8,11, en55024, en61547, lig ht industry level (surge 4kv), criteria a 13 ~ 20v 15.6 ~ 24v 19.5 ~ 30v 23.4 ~ 36v 35.1 ~ 54v 31.2 ~ 48v 27.3 ~ 42v rated current 4.8a 4a 3.2a 2.65a 1.77a 2a 2.28a constant current operation voltage note.5 17 ~ 22v 22 ~ 27v 27 ~ 33v 33 ~ 40v 49 ~ 58v 43 ~ 53v 37 ~ 46v voltage adj. range (svr1) current adj. range (svr2) 3.12 ~ 4.8a 2.6 ~ 4a 2.08 ~ 3.2a 1.72 ~ 2.65a 1.15 ~ 1.77a 1.3 ~ 2a 1.48 ~ 2.28a file name:cen-100-spec 2011-07-28 ? features : 100w single output led power supply c e n - 1 0 0 s e r i e s universal ac input / full range (up to 295vac) protections: short circuit / over current / over voltage / over temperatu re output voltage and constant current level adjustable built-in active pfc function ip66 design for indoor or outdoor installations cooling by free air convection 100% full load burn-in test high reliability suitable for led lighting and moving sign applications compliance to worldwide safety regulations for lighting suitable for dry / damp / wet locations 3 years warranty features : f emc immunity emc emission
t case 31.25 t case: max. case temperature. mechanical specification file name:cen-100-spec 2011-07-28 case no. 993a unit:mm derating curve static characteristics ambient temperature ( ) load (%) -30 -25 -5 0 15 30 50 60 70 20 40 60 80 100 input voltage (v) 60hz 90 100 125 135 145 155 165 175 180 200 230 295 100 90 80 70 60 50 40 load (%) (horizontal) fosc : 42khz(115vac) 68khz(230vac) detection pwm & pfc circuit o.l.p. emi filter rectifiers power switching filter & rectifiers +v -v i/p fg control o.v.p. & o.c.p. 40.5 86 io vo adj. adj. 100w single output led power supply c e n - 1 0 0 s e r i e s block diagram 30.6 45 62.5 7.6 10.5 4.6 4pl 300 20 sjtw 18awg 3c 300 20 -v(black) +v(red) svt 18awg 2c fg (green/yellow) ac/l(brown) ac/n(blue) 30.64 172 193
54 58 62 66 70 74 78 82 86 90 94 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 277vac 230vac 115vac 0 .7 8 0 .8 0 0 .8 2 0 .8 4 0 .8 6 0 .8 8 0 .9 0 0 .9 2 0 .9 4 0 .9 6 0 .9 8 1 .0 0 5 0 % 6 0 % 7 0 % 8 0 % 9 0 % 1 0 0 % 2 7 7 v a c 2 3 0 v a c 1 1 5 v a c power factor characteristic efficiency vs load (48v model) cen-100 series possess superior working efficiency that up to 91% can be re ached in field applications. pf load efficiency (%) load there are two major kinds of led drive method "direct drive" and "with led driv er". a typical led power supply may either work in "constant voltage mode (cv) or c onstant current mode (cc)" to drive the leds. mean well's led power supply with cv+ cc characteristic can b e operated at both cv mode [with led driver, at area (a)] and cc mode [direct drive, at area (b)]. typical led power supply i-v curve vo(%) 100 65 50 100 (max.) io (%) constant voltage area constant current area hiccup protection (a) (b) (c) (100w) constant current mode 100w single output led power supply c e n - 1 0 0 s e r i e s file name:cen-100-spec 2011-07-28 driving methods of led module


▲Up To Search▲   

 
Price & Availability of CEN-100-24

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X